Haemacytometer sets

These sets comprise of a cell counting chamber, cover slips, pipettes (red cell and white cell), tubing and pipette holders and instructions on usage and cleaning. Each set is packaged in a sturdy plastic box.

The Cell Counting Chamber is molded from a single piece of thermal and shock-resistant glass. An H-shaped moat forms either one or two counting areas, or plateaus. Each plateau features an etched grid or ruling. The ruled surface is either 0.1mm or 0.2mm below the cover glass, limiting the Volume of 1 Square mm of blood or fluid over a square mm at 0.1cu.mm or 0.2cu.mm respectively.

Contact of the flat, polished cover glass surfaces with the cover glass supports produces an exact volume of fluid over the counting area.

The difference in surface tension characteristics between the metallic surface on the chamber and the polished cover glass assures smooth capillarity for precise loading and more even cell distribution.

2 cell rhodium coated

 

AC1000 + Z4 Improved Neubauer

A 2 cell rhodium coated (bright-line) counting chamber set to BS748 with cell depth of 0.1mm and an Improved Neubauer Ruling.

 

Prices and ordering

Usage   Cell Counts
Cell Depth   0.100mm +/- 1% (1/10mm)
Volume of 1 Square mm of 1 Square mm   0.1 Microliter
Ruling Pattern   Improved Neubauer, 1/400 Square mm
Rhodium coated (bright-line)   Yes
 

AC2000 + Z4 Neubauer

A 2 cell rhodium coated (bright-line) counting chamber set to BS748 with cell depth of 0.1mm and a Neubauer Ruling.

 

Prices and ordering

Usage   Cell Counts
Cell Depth   0.100mm +/- 1% (1/10mm)
Volume of 1 Square mm   0.1 Microliter
Ruling Pattern   Neubauer, 1/400 Square mm
Rhodium coated (bright-line)   Yes
 

AC5000 + Z4 Thoma

A 2 cell rhodium coated (bright-line) counting chamber set to BS748 with cell depth of 0.1mm and a Thoma Ruling.

 

Prices and ordering

Usage   Cell Counts
Cell Depth   0.100mm +/- 1% (1/10mm)
Volume of 1 Square mm   0.1 Microliter
Ruling Pattern   Thoma, 1/400 Square mm
Rhodium coated (bright-line)   Yes
 

AC6000 + Z4 Modified Fuchs Rosenthal

A 2 cell rhodium coated (bright-line) counting chamber set to BS748 with cell depth of 0.2mm and a Modified Fuchs Rosenthal Ruling. The Fuchs-Rosenthal Counting Chamber is used for Cerebro-Spinal Fluid cell counts.

 

Prices and ordering

 
     
Usage   Cell Counts
Cell Depth   0.200mm +/- 1% (1/5mm)
Volume of 1 Square mm   0.2 Microliter
Ruling Pattern   Modified Fuchs Rosenthal, 1/16 Square mm
Rhodium coated (bright-line)   Yes

2 cell standard

 

AS1000 + Z4A Improved Neubauer

A 2 cell counting chamber set to BS748 with cell depth of 0.1mm and an Improved Neubauer Ruling.

 

Prices and ordering

Usage   Cell Counts
Cell Depth   0.100mm +/- 1% (1/10mm)
Volume of 1 Square mm   0.1 Microliter
Ruling Pattern   Improved Neubauer, 1/400 Square mm
Rhodium coated (bright-line)   No
 

AS2000 + Z4A Neubauer

A 2 cell counting chamber set to BS748 with cell depth of 0.1mm and a Neubauer Ruling.

 

Prices and ordering

Usage   Cell Counts
Cell Depth   0.100mm +/- 1% (1/10mm)
Volume of 1 Square mm   0.1 Microliter
Ruling Pattern   Neubauer, 1/400 Square mm
Rhodium coated (bright-line)   No
 

AS3000 + Z4A Burker

A 2 cell counting chamber set with cell depth of 0.1mm and a Burker Ruling.

 

Prices and ordering

Usage   Cell Counts
Cell Depth   0.100mm +/- 1% (1/10mm)
Volume of 1 Square mm   0.1 Microliter
Ruling Pattern   Burker, 1/25 Square mm
Rhodium coated (bright-line)   No

1 cell rhodium coated

 

BC1000 + Z4B Improved Neubauer

A single cell rhodium coated (bright-line) counting chamber set to BS748 with cell depth of 0.1mm and an Improved Neubauer Ruling.

 

Prices and ordering

Usage   Cell Counts
Cell Depth   0.100mm +/- 1% (1/10mm)
Volume of 1 Square mm   0.1 Microliter
Ruling Pattern   Improved Neubauer, 1/400 Square mm
Rhodium coated (bright-line)   Yes
 

BC2000 + Z4B Neubauer

A single cell rhodium coated (bright-line) counting chamber set to BS748 with cell depth of 0.1mm and a Neubauer Ruling.

 

Prices and ordering

Usage   Cell Counts
Cell Depth   0.100mm +/- 1% (1/10mm)
Volume of 1 Square mm   0.1 Microliter
Ruling Pattern   Neubauer, 1/400 Square mm
Rhodium coated (bright-line)   Yes

1 cell standard

 

BC3000 + Z4B Burker

A single cell rhodium coated (bright-line) counting chamber set to BS748 with cell depth of 0.1mm and a Burker Ruling.

 

Prices and ordering

Usage   Cell Counts
Cell Depth   0.100mm +/- 1% (1/10mm)
Volume of 1 Square mm   0.1 Microliter
Ruling Pattern   Burker, 1/25 Square mm
Rhodium coated (bright-line)   Yes
 

BS1000 + Z4C Neubauer

A single cell counting chamber set to BS748 with cell depth of 0.1mm and an Improved Neubauer Ruling.

 

Prices and ordering

Usage     Cell Counts
Cell Depth   0.100mm +/- 1% (1/10mm)
Volume of 1 Square mm   0.1 Microliter
Ruling Pattern   Improved Neubauer, 1/400 Square mm
Rhodium coated (bright-line)   No
 

BS2000 + Z4C Neubauer

A single cell counting chamber set to BS748 with cell depth of 0.1mm and a Neubauer Ruling.

 

Prices and ordering

Usage    Cell Counts
Cell Depth   0.100mm +/- 1% (1/10mm)
Volume of 1 Square mm   0.1 Microliter
Ruling Pattern   Neubauer, 1/400 Square mm
Rhodium coated (bright-line)   No
 

BS5000 + Z4C Thoma

A single cell counting chamber set to BS748 with cell depth of 0.1mm and a Thoma Ruling.

 

Prices and ordering

Usage   Cell Counts
Cell Depth   0.100mm +/- 1% (1/10mm)
Volume of 1 Square mm   0.1 Microliter
Ruling Pattern   Thoma, 1/400 Square mm
Rhodium coated (bright-line)   No